What is the cause of excessive water storage in the humidification system of Dongguan high and low temperature alternating damp heat test chamber?

What is the cause of excessive water storage in the humidification system of Dongguan high and low temperature alternating damp heat test chamber?
Haotian high and low temperature damp heat alternating test box is a necessary test equipment in aviation, automobile, home appliances, scientific research and other fields. It is used to test and determine electrical, electronic and other products and materials for high temperature, low temperature, alternating humidity and heat or constant test The parameters and performance after the temperature environment changes.
For example, the high and low temperature alternating damp heat test box has similar common faults such as low water alarm, overvoltage alarm, and load alarm. I don’t know how to deal with it? The professional technicians of Dongguan Haotian test equipment will explain to everyone. I look forward to helping everyone
Humidification system:
1. Shallow water humidification method
2. Humidifier control mode: non-contact and other periodic pulse width adjustment, SSR (solid state relay)
3. With automatic water level compensation and water shortage alarm system
4. Humidity control adopts PID + SSR system coordinated control in the same channel
5. Heating and humidifying power: far-infrared stainless steel high-speed heating (0.75KW×3) nickel-chromium alloy electric heating tube
In fact, most of the problems are not the common failures of the environmental test box that have destroyed the machinery and equipment. The basics are the ability to carry out calibration and other manual operations to solve the difficulties. Therefore, Haotian application staff does not need to worry when such problems occur. Because the processing method is very simple and the speed is also fast, there is no need to worry about harming the experiment.
Professional technicians need to interpret a more in-depth problem in the high and low temperature alternating damp heat test chamber . In some cases, Haotian will find water drops from the dry bulb temperature tube at the upper right of the personal studio of the constant temperature and humidity test chamber during the entire application process. , It is very harmful to the experiment, so users will be very worried about this problem. The actual solution is as follows: start with the situation first, open the door of the personal studio, and you will see a temperature sensor and a dry bulb in the upper right corner of the personal studio The temperature tube, and the environmental humidity sand cloth is suspended on the temperature sensor, and the bottom is immediately immersed in the dry bulb temperature tube. If there is a drop of water, it can be observed as soon as the tailgate is opened. .
After the high and low temperature alternating damp heat test box, everyone must open the control box to check the water channel, and observe whether the water valve is hit too much, resulting in too much water flow. If it is to immediately reduce the water inlet valve. In the second step, Haotian checked whether the moisturizing and moisturizing time was set too often, which resulted in excess water flow capacity.

Fluorescence Spectrometer

Fluorescence spectrum can provide excitation spectrum, emission spectrum, fluorescence intensity, quantum yield, fluorescence lifetime, fluorescence polarization and other more physical parameters. These parameters reflect various features of the molecules , and through which can obtain more information of the tested molecular. CNI launched fluorescence Spectrometer with the characteristics of rapid analysis and accurate measurement, is usually used in crystal, rare earth elements and other fluorescence spectrum detection. Fluorescence spectrum analysis and measurement is special in high sensitivity, strong selectivity, micro samples, simple operation, etc.

â–  Composition of Fluorescence Spectrometer

FC-D-Raman-laser
SP-gxgpy-1b (1)
SP-3b
Laser Source Fiber Optic Spectrometer Probe

A variety of linewidth options at :

257, 360, 405, 473, 514.5, 532, 633, 660,

785, 830, 980, 1064 nm

High sensitivity;

Up to 80% quantum efficiency;

Spectral range 200- 1100nm

Excitation wavelength;

360, 405, 532, 785, 830 nm...


â–  Fluorescence Spectrometer Solution

SP-Raman
SP-1b
Combined Fluorescence Spectrum System Portable Fluroescence Spectrometer

Fast connection, flexuble operation.

Wavelength is optional according on

Customer`s acyual requirements.

Simple measurement and easy operation,

extemal power supply vehicle- mounted charger,

Dustproof, anti- vibration, arti-glare interference...


SP-Raman-1a
SP-Raman-2a
Desktop Raman Flurocence Spectrometer Micro Flurocence Spectrum Measurement System

Build- in narrow line width laser- power

adjustable, high sensitivity spectrometer-

used for weak signal detection

It combines micro system and Raman

system which greatly tacilitates the Raman

micro area detection



â–  Sample Fluorescence Spectrum

Sample Fluorescence Spectrum


Combined Fluorescence Analyzer,Atomic Fluorescence Spectrometer,Fluorescence Spectrometer,X Ray Fluorescence Spectrometer

Changchun New Industries Optoelectronics Technology Co., Ltd. , https://www.lasersciences.com